UC1: PV Load Reconstruction – Results

UC1 involves estimating PV generation to enable the reconstruction of true net load. The accuracy of the estimated PV production is crucial here. 

Table: Model comparison and performance in UC1

Model ConfigurationInput Data UsedwRMSE(PV generation Estimation)
Simple BaselineHistorical Patterns Only20.5%
NWP EnhancedBaseline + NWP17.8%
EO EnhancedBaseline + EO Features17.0%
Best ConfigurationEO + NWP Fusion14.8%

The performance target for this complex task (isolating PV from the aggregated consumption) was a wRMSE of 14.8%. The reduction from the baseline (20.5%) confirms that EO inputs provide meaningful gains in reconstructing true consumption, giving the DSO more reliable planning inputs.